As one of the performance characteristics of the coagulation test agitator, automatic dosing is also a highlight of the users. Since many new friends are not very familiar with the self-dosing function, there will be some doubts when setting up the program. Today we will come. Focus on explaining how the coagulation test mixer is automatically tested.
Turn on the power switch, the LCD screen displays the main menu clearly and clearly. When the LCD displays the main menu, select button 2: Program, enter the program number: 1, and press the Enter key. At this time, the cursor flashes at the point to be input (in the upper left corner at the beginning), press the number keys to input each item in turn, and the cursor automatically shifts to the right and wraps. The time division and the second are two digits, and the rotation speed is three digits. When the high digit is zero, you should input “0” or press the “→” key to skip; when the speed is input, you can input the dosing information. If you want to add medicine at the beginning of the procedure, you should enter "1" (or other non-zero number). If you do not add medicine, you should enter "0". The final sedimentation procedure should set the rotation speed to "000". If there are other programs after the precipitation program, all of them are automatically deleted at this time. For example, if the minutes and seconds are all set to "00" in a certain section, the program starts from the beginning of the program, and the original programs are deleted. After the above data is set, press the 'Start' button, the agitator will run normally, and the automatic dosing will be realized. If you need to add the drug for each segment, according to the above method, you can set the dosing data of different segments to 1 and stir. In, will automatically add drugs
The advantages of automatic dosing are: 1. Excluding the influence of time drop factors on the effect of coagulation test in artificial dosing 2. Saving human resources and improving the labor intensity of workers 3. Stable and reliable operation
Tips: For the accuracy of the data, before adding the test tube, the ratio of the drug must be even!
Письмо этому поставщику
January 03, 2024
January 03, 2024
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.