Vacuum pump, diaphragm seal installation and use of mechanical requirements 1, mechanical seal on the accuracy of the machine requirements: (mechanical seal vacuum pump, for example)
(1) The radial runout tolerance of the shaft (or sleeve) on which the mechanical seal is to be mounted shall not exceed 0.04 to 0.06 mm.
(2) rotor axial movement does not exceed 0.3mm.
(3) The tolerance of the beating tolerance on the surface of the shaft (or sleeve) that the seal cavity and the seal cap are combined with should not exceed 0.04 ~ 0.06mm.
2, seal confirmation:
(1) Confirm that the seal installed is the same as the required model number.
(2) Before installation, it should be carefully compared with the assembly diagram, and the number of parts is complete.
(3) and the use of spring mechanical seal transmission, the spring left and right spin points, according to the rotation of the shaft to choose.
3, seal installation method:
Installation method with mechanical seal type, the type of machine varies, but its installation essentials are almost the same, the installation steps and precautions are as follows:
(1) to determine the installation dimensions: installation, the product should be used according to instructions or samples to ensure the installation of mechanical seal size.
(2) Prior to loading, the shaft (sleeve) and gland should be free from burrs and the bearing is in good condition; the seals, shaft, seal chamber and gland should be clean. In order to reduce the frictional resistance, the shaft should be coated with a thin layer of oil on the mechanical seal to lubricate. Considering the miscibility of rubber O-rings, soapy water should be applied if oil is not suitable. Floating static ring without anti-rotation of the structure should not be oiled, should be dry-loaded gland.
(3) Install the static ring and the gland together on the shaft first, be careful not to touch the shaft, then insert the moving ring assembly. Spring seat or drive seat set screws should be evenly tightened several times.
Before the gland is not fixed, push the compensation ring by hand for axial compression. After the release, the compensation ring can automatically rebound without jamming, and then the gland bolt is evenly locked.

This article Keywords Search: More Pumps Technical Articles Pumps Product Selling Leads

Согласим нас

Автор:

Mr. Bruce Tang

Электронная почта:

bruce.tang@macxipump.com

Phone/WhatsApp:

+8613773149257

Популярные продукты
Вам также может понравиться
Связанные категории

Письмо этому поставщику

Тема:
Электронная Почта:
сообщение:

Ваше сообщение MSS

Согласим нас

Автор:

Mr. Bruce Tang

Электронная почта:

bruce.tang@macxipump.com

Phone/WhatsApp:

+8613773149257

Популярные продукты

Главная

Product

Whatsapp

О нас

Запрос

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Отправить