Suzhou Macxi Fluid Technology Co.,Ltd.
Главная> Блог> Roots pump - water ring pump vacuum unit explain the working principle

Roots pump - water ring pump vacuum unit explain the working principle

June 20, 2022
Roots vacuum pump (mechanical booster pump) for higher vacuum can not be directly into the atmosphere, such as the straight row atmosphere will cause the Roots vacuum pump inlet and exhaust pressure is too large, so Roots vacuum pump overload, such as simple Increasing the Roots vacuum pump motor power will in turn cause the Roots vacuum pump to overheat so that the small gap between the Roots vacuum pump rotors quickly becomes stuck due to thermal expansion. In order to ensure Roots vacuum pump can achieve a higher vacuum Roots vacuum pump rotor clearance must be guaranteed. Therefore, Roots vacuum pump must be used before the stage pump, pump with the former stage to pump pressure within the system to a certain range and then start Roots vacuum pump, Roots vacuum pump so to avoid overloading. Pre-stage pump can be used water (liquid) ring vacuum pump, rotary vane vacuum pump, slide valve vacuum pump, reciprocating vacuum pump can be directly to the atmosphere of the vacuum pump. Roots vacuum unit under normal circumstances, the selection of water ring pump as the fore-pump than other vacuum pumps is more favorable, mainly because it can extract a large amount of condensable steam, especially when the gas seal mechanical vacuum pump can be excluded condensable Inadequate steam capacity, or use of solvents that can deteriorate the pump oil and affect performance, or when the vacuum system does not allow oil contamination becomes even more pronounced. Roots pump - water ring pump unit is widely used in chemical industry, food sublimation drying, high-altitude simulation test vacuum system. Such joint unit, there are roughly the following types. (1) Roots pump - water ring pump: The role of the water ring pump in the unit is to create the required vacuum for the Roots pump, thus requiring the maximum allowable discharge pressure of the water ring pump, that is, on the one hand, Increase the water pump ultimate vacuum, on the other hand, we must try to improve the maximum allowable exhaust pressure Roots pump. In general, the single-stage water ring pump ultimate vacuum is not high, but at present China's production of the Roots pump requires pre-vacuum is higher, so in fact not a single-stage water ring pump as the Roots pump pump, and use The double-stage water ring pump, which can increase the ultimate vacuum, can be used as a fore-stage pump. The double-stage water ring pump can also increase the ultimate vacuum of the unit. The ultimate vacuum of a Roots pump is low, especially when it is operated in combination with a water ring pump. The range of use is limited and the ultimate vacuum of the entire unit may be lower. However, if two Roots pumps are used in series Combined with the water ring pump, you can greatly increase the unit's ultimate vacuum. Therefore, it is common to see in this type that two Roots pumps are connected in series and then use a two-stage water ring pump for the foreline pump to form a unit. (2) Roots pump - water ring pump - air pump unit: even with a two-stage water ring pump, the ultimate vacuum increase is only within a certain range, which is limited by the saturated vapor pressure of water. The theoretical ultimate pressure of water ring pump is the saturated vapor pressure of water. Considering the influence of gas backflow and other factors, in fact the ultimate pressure of the water ring pump is significantly higher than the saturated steam pressure at the water temperature. In order to improve the ultimate vacuum level pump, you can also make the water ring pump and atmospheric pump combination. In this way, the series vacuum pump ultimate vacuum of up to 20 ~ 30Torr, if the water ring pump and the two stage air pump combination, the ultimate vacuum up to 2 ~ 10Torr. (3) Roots pump - water ring pump parallel mechanical vacuum pump: This unit is mainly used for vacuum treatment system that needs to handle a large amount of water vapor, and the ultimate vacuum requirements are high, for example, in vacuum drying. In a vacuum system that requires a large amount of water vapor, a water ring pump is suitable, but due to its low ultimate vacuum, the ultimate vacuum of the entire unit is low. Although vacuum systems requiring a higher degree of vacuum require a mechanical vacuum pump with a higher ultimate vacuum to be used as a foreline pump. However, due to water ring pump power consumption, low efficiency, high noise, in a long time vacuum drying system, the water ring pump as the Roots pump is not economical. In these circumstances, the gas-town mechanical vacuum pump can be connected in parallel with the water ring pump, as the Roots pump pump. Vacuum drying, the first water pump pre-pumping, until a substantial reduction in water vapor, and then open the gas mechanical town vacuum pump, cut off the water ring pump. If you need more time to complete the drying occasion, the required cooling water and power are less, as shown in Figure 3. Roots pump - water ring pump unit operation 1) unit front condenser To try to make the unit smaller, you can try to make the steam to be drawn in before entering the pump unit condensation, so that the remaining non-condensable gas And traces of residual steam. The volume of the gas decreases at the same pressure after cooling. Therefore, the amount of air required after condensing is reduced, and accordingly, the pump can be selected to be smaller. Which way is more economical? As the case may be, for example as follows: There are two ways to condense steam: one is to install a cooling device and the other is to install a condenser in the high-pressure stage of the unit so that ordinary water cool down. The system requires 50kg of water vapor per hour, with a volume flow of 50000m3 / h at a suction pressure of 1Torr. 1) To suck the amount of water vapor above, three Roots pumps are required in series, and a water ring pump is used to make up the unit of the previous stage. The total power of this unit is 90kW. 2) To condense the steam before it reaches the vacuum pump, a condenser and a cooling device with a power of 30000kcal / h are installed at A, as shown in Figure 4. In 1Torr suction pressure, the steam condensing temperature is -19 ℃, in order to ensure continuous operation, the condensing unit should take the condensing temperature of -25 ℃, and the installation of two parallel condenser. Based on the composition of the non-condensable gases, the amount of suction in the vacuum pump can be reduced to 1000-2000m3 / h. The power of the main unit (including the condenser's power consumption) is also 90kW. 3) Roots pump out the water vapor, and under 45Torr pressure condensation, the pressure of some condensing temperature is about 36 ℃, so condensing the condenser can be maintained at a temperature between 30 ~ 35 ℃, available ordinary Cooling water cooling. The condenser is located at B. At this time the total power consumption is about 75kW. Through the comparison of the above three groups shows that the third option is the best, can reduce the power consumption of 15kW. In summary, only the non-condensable gas is left after the steam is cooled. When the pressure is low, the specific volume of water vapor is quite large. After condensable condensables, the amount of pumping required by the pump is obviously reduced. In addition, whether the steam is condensed or not, the volume flow will be reduced at the same pressure as long as the gas temperature decreases. For example, chemical processes 200 ~ 300 ℃ temperature of the gas is not uncommon. After cooling from 300 ° C to 50 ° C, the volume of dry air is reduced by about 45% so that a smaller capacity suction vacuum pump unit can be selected. (2) The sequence of operation of the unit: 1) When there is no by-pass valve in the unit, the water ring pump should be started first. The gas in the system being pumped is tapped by the Roots pump (the gas drives the Rotor pump rotor to rotate on its own, Into the water ring pump and then discharged to the atmosphere until the water ring suction pressure pump (such as series with the air pump, the suction pressure of the air pump) to Roots pump initial provisions (that is, allow the exhaust pressure), before Start Roots pump, the unit officially started to work. 2) When there is a bypass valve in the unit, as shown in Fig. 5, start the water ring pump first and then start the Roots pump. At this moment, the pressure difference between inlet and outlet of Roots pump is large, bypass valve is opened automatically, Part of the gas in the container through the bypass valve into the water ring pump, the other part of the pump under the action of the Roots through the pump into the water ring pump, evacuation rate is obviously increased, so quickly to Roots pump pre-vacuum into Exhaust pressure is smaller, the valve automatically closed (or manually shut down), the crew officially work. This method can greatly shorten the pre-pumping time, but the equipment is more complicated. (3) unit - Roots pump - forepump performance relationship The performance of the unit is closely related to the performance of the Roots pump, and Roots pump performance with the previous stage of the pump is different. 1) Roots pump due to the rotor and rotor, there is a gap between the rotor and the housing, so there is a backflow, and this backflow by the inlet pressure and outlet pressure of the impact, even with the same Roots pump , The use of different fore pump, its pumping rate will be different. Roots pump pumping rate can be determined by the following formula: δ = δ0 (P2 / P1 / K) Where: δ0-design of the pumping rate; P1-inlet pressure; P2- outlet pressure; K- intrinsic constant, Pump rotor shape, the amount of clearance, the rotor peripheral speed and outlet pressure to determine. As can be seen from the above formula, the amount of suction is affected by the ratio of the outlet pressure to the inlet pressure. That is, if the suction rate of the foreline pump is increased, the pumping rate of the Roots pump also increases. (2) The ultimate pressure is determined by the pumping speed of the pump, the return flow of each clearance, the amount of pump leakage, and the amount of deflation on the high vacuum side. That is: P0 = (Q1 + Q2 + Q3) / δ Where: P0 - the ultimate pressure; δ - pumping rate; Q
Согласим нас

Автор:

Mr. Bruce Tang

Электронная почта:

bruce.tang@macxipump.com

Phone/WhatsApp:

+8613773149257

Популярные продукты
Вам также может понравиться
Связанные категории

Письмо этому поставщику

Тема:
Электронная Почта:
сообщение:

Ваше сообщение MSS

Согласим нас

Автор:

Mr. Bruce Tang

Электронная почта:

bruce.tang@macxipump.com

Phone/WhatsApp:

+8613773149257

Популярные продукты

Главная

Product

Whatsapp

О нас

Запрос

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Отправить