Identification of Leybold Vacuum Pump Oil Deterioration and Principle of Pump Oil Replacement


After a period of use, the Leybold vacuum pump oil deteriorates the vacuum pump oil due to contamination of mechanical impurities and dust from the outside, metal chips worn by the running parts, and metal salts formed by erosion of the parts. After the vacuum pump oil has deteriorated, it is dark black, foamy and emulsified. It is rubbed with fingers, has no sticky feeling, cyanosis or odor, and it is dark brown on the white test paper, and there is no yellow infiltration area or black spots. If it is not replaced in time, it will accelerate the wear and tear of parts, affect the service life, and even cause safety accidents. Therefore, it is especially important to check whether the lubricating oil has deteriorated and replaced in time. Several simple identification methods are introduced as follows:
1) Oil flow observation method: take two measuring cups, one of which is filled with vacuum pump oil to be inspected, the other is placed on the table, and the measuring cup filled with vacuum pump oil is lifted off the table 30-40 cm and tilted to allow the vacuum pump The oil slowly flows into the empty cup and observes the flow. The vacuum pump oil with good quality should be slender, even and continuous. If there is a sudden flow of oil, sometimes there is a large flow, then the vacuum pump The oil has deteriorated.

2) Hand rubbing method: the vacuum pump oil is rubbed repeatedly between the thumb and the index finger. The better vacuum pump oil hand feels lubricity, less wear debris, no friction, if you feel the friction between the fingers and the like Sense, it means that there are many impurities in the vacuum pump oil, can not be used again, should replace the vacuum pump oil.

3) Illumination method: On a clear day, use a tool to pry the vacuum pump oil at a 45-degree angle to the horizontal plane. In view of the sunlight, observe the oil droplets. Under the light, it can be clearly seen that there is no wear debris in the vacuum pump oil, which can continue to work. If there is too much wear debris, the vacuum pump oil should be replaced.

4) Oil droplet trace method: Take a clean white filter paper, and drop a few drops of oil on the filter paper. After the vacuum pump oil leaks, if there is black powder on the surface, touch the hand with a feeling of resistance, then the vacuum pump oil There are a lot of impurities inside. The good vacuum pump oil has no powder, and it is dry and smooth by hand, and it has yellow marks.

Leybold vacuum pump oil change principle
1) When the vacuum falls, the vacuum pump oil can not meet the need;
2) When the vacuum pump oil becomes darker and brown, it should be vacuum pumped;
3) When the acid value of the oil reaches 2.0mgKOH/g, consider replacing the new vacuum pump oil.
Shanghai website: http://


Согласим нас

Автор:

Mr. Bruce Tang

Электронная почта:

bruce.tang@macxipump.com

Phone/WhatsApp:

+8613773149257

Популярные продукты
Вам также может понравиться
Связанные категории

Письмо этому поставщику

Тема:
Электронная Почта:
сообщение:

Ваше сообщение MSS

Согласим нас

Автор:

Mr. Bruce Tang

Электронная почта:

bruce.tang@macxipump.com

Phone/WhatsApp:

+8613773149257

Популярные продукты

Главная

Product

Whatsapp

О нас

Запрос

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Отправить